All-in-one AC Coupled Unit

4.0/5.0/6.0/8.0/10.0/12.0

TSUN offers an all-in-one AC Coupled Unit, which simplifies the whole energy storage system's installation process. The ACS series is composed of an AC coupled inverter, battery bank and pre-wired BMS system inside of a modern cabinet, embedded with connection devices and preset cable slot. Simple to install, safe, very reliable, and provides the lowest lifetime energy cost for retrofit customers.

Highlights:

  • All-in-one design, no extra match.
  • Easier installation.
  • All-in-one design unified after-sale service.
  • Larger battery, more power available.
  • Excellent battery supplier ensure high-quality battery.
  • Rich experience professional solution provider.
  • IEC/EN 62619 certification.

All-in-one AC Coupled Unit System

TECHNICAL DATA

  • Model TSOL-ACU4K-T TSOL-ACU5K-T TSOL-ACU6K-T TSOL-ACU8K-T TSOL-ACU10K-T TSOL-ACU12K-T
    Battery Type LiFePO4
    Battery Capacity per Kit [kWh] 5.12
    Battery Voltage per Kit [V] 102.4
    Max. Battery Quantities per System 3 (Up to 15.36 kWh)
    Max. Charging Power [W] 4000 5000 6000 7500 7500 7500
    Max. Charging/ Discharging Current [A] 25 / 25
    Max. Battery Charging/ Discharging Efficiency 97.2% / 97.2% 97.3% / 97.3%
  • Model TSOL-ACU4K-T TSOL-ACU5K-T TSOL-ACU6K-T TSOL-ACU8K-T TSOL-ACU10K-T TSOL-ACU12K-T
    Rated Output Power[W] 4000 5000 6000 8000 10000 12000
    Max. Output Power [VA] 4400 5500 6600 8800 11000 13200
    Max. Output Current [A] 6.7 8.3 10 13.3 16.5 20
    Max. Input Apparent Power[VA]* 8000 10000 12000 16000 16500 16500
    Rated Output Voltage [V] 230 / 400, 3L/ N/ PE
    Rated Grid Frequency [Hz] 50 / 60
    Power Factor [cos φ] 0.8 leading~0.8 lagging
    Total Harmonic Distortion [THDi] <3%
  • Model TSOL-ACU4K-T TSOL-ACU5K-T TSOL-ACU6K-T TSOL-ACU8K-T TSOL-ACU10K-T TSOL-ACU12K-T
    Max. Apparent Output Power [W] 4400 5500 6600 8800 11000 13200
    Peak Output Apparent Power per Phase [VA]*** 1600 2100 2600 3300 4000 5000
    Rated Output Voltage [V] 230 / 400, 3L/ N/ PE
    Rated Output Frequency [Hz] 50/60
    Total Harmonic Distortion of Voltage <3%
    Switch Time [ms] <10
    Peak Output Apparent Power [VA]** 8000VA, 60sec 10000VA, 60sec 12000VA, 60sec 16000VA, 60sec 20000VA, 60sec 20000VA, 60sec
  • Model TSOL-ACU4K-T TSOL-ACU5K-T TSOL-ACU6K-T TSOL-ACU8K-T TSOL-ACU10K-T TSOL-ACU12K-T
    AC Short Circuit Protection Integrated
    Overload Protection Integrated
    Insulation Resistance Protection Integrated
    Surge Protection Integrated
    Residual Current Protection Integrated
    AC Overvoltage/Undervoltage Protection Integrated
    AC Overfrequency/Underfrequency Protection Integrated
    Over Temperature Protection Integrated
    Anti-islanding protection Integrated
  • Model TSOL-ACU4K-T TSOL-ACU5K-T TSOL-ACU6K-T TSOL-ACU8K-T TSOL-ACU10K-T TSOL-ACU12K-T
    Battery Connection Type Quick Connector
    AC Connection Type Terminal
    Display LED+OLED
    Communication port CAN *2/ RS485 *2
    Communication Wi-Fi / 4G(Optional)
  • Model TSOL-ACU4K-T TSOL-ACU5K-T TSOL-ACU6K-T TSOL-ACU8K-T TSOL-ACU10K-T TSOL-ACU12K-T
    Topology Transformerless
    Over Voltage Category Main : III
    Ingress Protection IP65
    Operating Temperature Range -30~+60℃
    Ambient Humidity 0~100%
    Altitude 4000m(>3000m power derating)
    Noise[dBA] <25
    Cooling method Natural Convection
    Dimensions[H*W*D][mm]
    Weight[kg]
    Standard Warranty[year]

*Max apparent power from the grid means the maximum power imported from the utility grid used to satisfy the backup loads and charge the battery.

**The output power will exceed the rated value only when the power in the PV array is sufficient, and the duration of the overload is relating to the overload power.

***Only one of the three phases can reach up to 1.25 times, and the other two phases should be less than 1.1.

Online Inquiry

If you are interested in our products, or have any suggestions, please fill and submit your inquiry information below, we will reach back to you asap.