Microinverter
TSOL-MP2250

For more demanding environments, TSUN TSOL-MP2250 supports up to four high power panels at once, maximizing the power your installation can generate. The inverter is mounted directly near the solar module in the shade and is only responsible for the connected modules. This microinverter is therefore perfect for small systems and module areas with partial shading.

Highlights:

  • Maximum outpout power up to 2250W
  • Compatible with 182/210 solar module
  • Individual power conversion, 4 MPPTs, fits for complicated installation environments
  • Unqiue topology design, Peak efficiency up to 97%
  • Max DC voltage 60V, no risk for DC Arc
  • Comply with the requirements of rapid shutdown
  • Integrated with a communication module
  • "One-button" networking configuration with multiple microinverters at the same time, unique monitoring solution
  • Plug and play design, fast installation and wiring
  • IP67 design, hign level of dustproof and waterproof, suitable for outdoor use
  • Unique radiating fin design, good heat dissipation, longer life time

Microinverter TSOL-MP2250 System

TECHNICAL DATA

  • Model TSOL-MP2250
    Quantity of Input 4 Inputs 4 Panels
    Recommended Module Power (W) 480 ~ 700+
    Start up Voltage per Input@Rated condition (V) 22
    Mppt Voltage Range per Input (V) 18~60
    Max. Input Voltage per Input (V) 60
    Max. Short-circuit Current per Input(A) 20
    Max. Input Current per Input (A) 18.5
    Quantity of MPPT 4
  • Model TSOL-MP2250
    Max. Output Power (VA) 2250
    Nominal Continous Output Power (W) 2250
    Nominal Output Current (A) 10.1
    Max. Output Current (A) 11
    Nominal Output Voltage/Range (V)* 220/230/240(175~270), L/N/PE
    Nominal Frequency (Hz)* 50/60
    Power Factor >0.99 default, 0.8 leading … 0.8 lagging
    Output Current Harmonic Distortion <3%
  • Model TSOL-MP2250
    Peak Inverter Efficiency 97.0%
    CEC Weighted Efficiency 96.5%
    Nominal Mppt Efficiency 99.9%
  • Model TSOL-MP2250
    Anti-Islanding protection Integrated
    Insulation monitoring Integrated
    AC surge protection TYPE II
    Residual current monitoring Integrated
    AC overcurrent protection Integrated
    AC short-circuit protection Integrated
    AC overvoltage protection Integrated
    Over-heat protection Integrated
  • Model TSOL-MP2250
    Dimensions (W×H×D mm) 354 * 294 * 60
    Weight [kg] 6.4
  • Model TSOL-MP2250
    Night Time Power Consumption <1W
    Display LED indicators; TSUN APP+WEB
    Communication Built-in WiFi module; 4G module (Optional)
    Type of Isolation Transformerless
    Type of Enclosure IP67
    Cooling Natural convection
    Operating Ambient Temperature Range -25 ~ +65 °C (derating of over 50°C Ambient Temperature)
    Relative Humidity 100%
    Max. Operating Altitude Without Derating [m] 2000

* The AC voltage and frequency range may vary depending on specific country grid.

Online Inquiry

If you are interested in our products, or have any suggestions, please fill and submit your inquiry information below, we will reach back to you asap.